EPA 608 Type 1 Practice Test

Master small appliance definitions (≤5 lbs factory charge), passive system-dependent recovery rules, and A3 flammable refrigerant precautions.

Official target: 25 questions in 45 minutes (72% required) · 41 regulation-cited pool items · Primary text: U.S. EPA 40 CFR Part 82, Subpart F (§82.150–§82.169)

Type I (Small Appliances)

Question 1 of 15 · Small Appliance Charge & Scope

A motel maintenance tech holds only an EPA Type I card and is asked to service four units: a 2-lb window A/C, a 3.5-lb PTAC, a 4-lb field-piped mini-split, and a car A/C. Which rule defines which units fall under Type I?

Jump to any question (0/15 answered)

Independent preparation tool. Not affiliated with, endorsed by, or sponsored by the U.S. EPA, ESCO Group, Mainstream Engineering, or any EPA-approved certifying organization. We do not administer official exams or issue Section 608 technician cards.

Type I (Small Appliances) blueprint and domain weights

Requires 18/25 (72%) plus passing Core.

Exam domain Weight Primary citation Tested workplace decisions
Small Appliance Definitions & Recovery Thresholds 45% 40 CFR §82.152 & §82.156(a)(1) Factory-charged ≤5 lbs units, 80% vs. 90% recovery, and 4 inHg alternative rule.
Piercing Valves, Hydrocarbons & Passive Recovery 35% 40 CFR §82.156 & SNAP Rules Non-operating compressor procedures, R-600a/R-290 flammability precautions, and Schrader fittings.
Safe Disposal & Documentation 20% 40 CFR §82.155 Final processor verification statements and recordkeeping requirements.

Related study charts and exam modules

Frequently asked questions

What qualifies an appliance as EPA 608 Type I? +

Under 40 CFR §82.152, a small appliance is manufactured, charged, and hermetically sealed in a factory with 5 pounds or less of refrigerant.

What is the difference between 80% and 90% Type I recovery? +

Post-Nov 15, 1993 Type I recovery equipment must recover 90% of refrigerant when the compressor operates or 80% when the compressor is non-operating (or reach 4 inHg vacuum).

Can system-dependent passive recovery be used on hydrocarbon R-600a units? +

Safety standards restrict ungrounded or spark-prone equipment with A3 flammable refrigerants; verify equipment compatibility and follow SNAP venting exemptions vs. safe discharge procedures.

Unlock the full EPA 608 simulator once

Pay once via Waffo Checkout. Access ends cleanly after your study window with zero recurring billing across all 41 verified items.

Full pass guarantee terms →

7-Day Cram Pass

$14.99 one-time for 7 days

Full EPA 608 question bank, 1:1 timed exam simulator, missed-question drill, and flashcards for 7 days. Stops automatically, with zero auto-renewal.

Focused 7-day cram window (Pass Guarantee excluded)

Get 7-Day Cram Pass

30-Day Exam Pass

$24.99 one-time for 30 days

Full EPA 608 simulator access for 30 days plus our Conditional Pass Guarantee. One-time payment, expires automatically.

Includes Conditional Pass Guarantee (pass fee refund or 90-day extension)

Get 30-Day Exam Pass

90-Day Extended Pass

$34.99 one-time for 90 days

Complete 90-day EPA 608 prep window with Conditional Pass Guarantee for technicians or managers studying across schedules.

Includes Conditional Pass Guarantee (pass fee refund or 90-day extension)

Get 90-Day Extended Pass

Applies only to 30-Day and 90-Day passes. Never covers third-party official proctor or testing center registration fees. Independent preparation tool. Not affiliated with, endorsed by, or sponsored by the U.S. EPA, ESCO Group, Mainstream Engineering, or any EPA-approved certifying organization. We do not administer official exams or issue Section 608 technician cards.

Regulatory Sources & Methodology

All practice scenarios, evacuation limits, cooking thresholds, and passing benchmarks are authored directly from public-domain federal regulations rather than recalled or proprietary test content.